Skip to content

Solutions / Aircraft seals

Hold the boundary. Protect the system.

Fire seals, flammable fluid seals, and pressure and aerodynamic seals shaped to the interface they have to hold.

Wherever two parts of an aircraft meet, a gap can let fire cross a firewall, fluid escape into a fire zone, pressure drop or air move where it should not. AkroFire designs flexible seals around the actual interface: the penetration or joint, the hardware around it, the conditions it sees in service and what failure would mean for the aircraft.

Fire exposure 15 min at 2000°F
Seal types Fire, fluid, pressure, airflow
Certified and qualified
Certifications ›
  • Quality system · Amtivo AS9100D
  • Quality management · Amtivo ISO 9001:2015
  • [Description pending] AC20-135
  • [Wording pending] FAA-PMA

Seal types

Start with what the seal must control

Fire, fluid, pressure and airflow create different sealing requirements.

  1. 01

    Aircraft fire seals

    What it does
    Protects firewall penetrations from fire
    Where it is used
    Fuel and fluid lines, harnesses, ducts and structure crossing a firewall
    Jump to section
  2. 02

    Flammable fluid seals

    What it does
    Contains leaked fluid within the fire zone
    Where it is used
    Cowl doors, bulkheads and actuators in powerplant fire zones
    Jump to section
  3. 03

    Pressure seals and gaskets

    What it does
    Maintains the boundary between connected parts
    Where it is used
    Joints and interfaces that must retain pressure
    Jump to section
  4. 04

    Aerodynamic and door seals

    What it does
    Keeps airflow where the system needs it
    Where it is used
    Doors and other aerodynamic interfaces
    Jump to section

Fire seal or fluid seal?

A fire seal and a fluid seal do different jobs and are not interchangeable. A fire seal keeps flame from crossing a firewall penetration. A flammable fluid seal keeps leaked fluid inside the zone. Some interfaces need both, and an AkroFire engineer can help sort out which applies.

Aircraft fire seals

Close the opening. Protect the boundary.

Aircraft firewalls have numerous penetrations, and every one is a potential path for fire. Firewall penetrations bring lines, ducts, wiring and structure together with limited clearance or irregular geometry, where a rigid seal can be difficult to fit or leave gaps. AkroFire designs and manufactures flexible fire seals for fuel lines, fluid lines, electrical lines and harnesses, fan and bleed-air ducting, and structural components in powerplant, nacelle and APU fire zones. Each seal is shaped around the penetration and adjacent hardware, including any specified movement or thermal expansion.

Fire seal shapes

Flexible fireproof material, custom molded to fit your application.

Materials tested and proven to AC 20-135A / SAE AS6826Manufactured and inspected in an AS9100D certified facility

Fire performance

15 minutes. 50 square inches. No burn-through.

When correctly specified, AkroFire fire seals block both the ISO and FAA standard fire test flames for 15 minutes without burn-through or backside ignition.

Duration 15 minutes
Minimum test area 50 in²
Outcome 0 burn-through
ISO test flame
1100°C at 116 kW/m²
FAA test flame
2000°F at 9.310 BTU/ft²·s
Test area
At least 50 in² (322 cm²)
Duration
15 minutes
Outcome
No burn-through or backside ignition

These figures do not set a universal temperature, pressure or dimensional limit for every seal design. Product selection and qualification records determine suitability for the exact configuration.

Shaped to the penetration

Aircraft fire seals

Shaped for what crosses the firewall

Construction follows the line, duct, harness or structural feature passing through the firewall, along with the opening, seal land, nearby hardware, heat exposure, and movement or access needs. Material and seal profile are chosen for the fire requirement and the finished design.

On the same aircraft, a fire seal often works alongside a thermal blanket or insulation assembly, with the seal protecting the penetration and the blanket protecting adjacent surfaces.

Flammable fluid seals

Contain the leak. Protect the zone.

Aircraft powerplant fire zones must retain any flammable fluids that leak within them. A leak can put fluid or vapor near heat or another ignition source, and a seal that fails to contain it can turn a contained problem into a fire. AkroFire designs flexible flammable fluid seals for cowl doors, bulkheads and actuators in powerplant fire zones, each fitted to its interface to keep fluid from escaping into surrounding areas.

There is no single rating that suits every fluid seal. The design depends on the fluid and its compatibility with seal materials, service temperatures and pressures, interface geometry, and how the seal is installed and retained. AkroFire works from those requirements to define the construction and qualification approach.

Compliance

Support the aircraft-level compliance case

Flammable fluid fire-protection requirements appear in 14 CFR 25.863 for transport-category airplanes, 27.863 for normal-category rotorcraft and 29.863 for transport-category rotorcraft. The applicable rule depends on the aircraft certification basis, and compliance is shown at the aircraft level through analysis or testing. AkroFire supports developmental planning and qualification with the program team.

14 CFR 25.863 Transport-category airplanes
14 CFR 27.863 Normal-category rotorcraft
14 CFR 29.863 Transport-category rotorcraft
  • Pressure seals
  • Gaskets
  • Boots
  • Door seals

Pressure, gasket and aerodynamic seals

Keep pressure and airflow where the system needs them.

When an interface must retain pressure, the seal has to suit the joint, the operating conditions and the space available for installation. At an aerodynamic interface, such as a door, gaps can allow unwanted air movement or leakage, so the seal profile has to work with the shape of the interface and the conditions around it. AkroFire applies the same application-driven approach to pressure seals, gaskets, boots and door seals. Share the interface and what it must hold to start the conversation.

Talk to an engineer
Purpose-built tooling

Tooling

Complex shapes. Purpose-built tooling.

The fit is engineered for the interface, not pulled from a standard profile.

Seal geometry is often dictated by surrounding structure, equipment and installation space. AkroFire’s advanced tooling methods make it possible to produce seals in virtually any shape, so the seal can follow the interface instead of forcing the interface to accept a standard part.

To start a design review, share what you know about

  • 01
    The aircraft zone and the penetration, joint or interface
  • 02
    A drawing, model or dimensions, plus firewall or structure material and thickness
  • 03
    What the seal must contain or control, including fluid identification
  • 04
    Temperature, pressure, movement, vibration or thermal expansion requirements
  • 05
    Clearance, installation and removal needs, and the applicable fire requirement

You do not need a finished specification. A clear description of the problem is enough for an engineer to identify what else is needed.

Quality management systemAS9100D
Quality management systemISO 9001:2015

Quality and qualification

Quality systems and qualification support

Certifications and fire-test performance answer different questions.

AkroFire is certified to AS9100D and ISO 9001:2015 for its quality management systems. These company-level certifications support controlled manufacturing and inspection but do not approve a specific seal. Fire requirements and acceptance criteria depend on the aircraft and configuration. AkroFire has decades of in-house fire testing experience and currently tests some products in-house. While AkroFire transitions to a newer, larger facility, fire testing for new part development is supported through external partners and facilities, and AkroFire continues to guide developmental planning and qualification.

FAQ

Questions engineers ask

Start with the main job the seal must do. A fire seal protects a firewall penetration from fire exposure. A flammable fluid seal contains leaked fluid within a powerplant fire zone. If the interface involves both risks, describe both when you contact AkroFire.

Bring us the interface

Tell us what must stay in, stay out or stay under control. Share the aircraft zone, the interface and the requirement you are working to, and an AkroFire engineer will help define the seal and the next step for your program.

Talk to an engineer